S.No. EARTH WORK Unit Quantity Rate Amount
1 Excavation for foundation etc, in ordinary soil up to required depth including dressing, leveling of all surfaces, stacking at appropriate place, of excavated earth suitable for back filling, complete in all respect. Cft 12 0
2 Excavation for foundation etc, in Rock up to required depth including dressing, leveling of all surfaces, stacking at appropriate place, of excavated earth suitable for back filling, complete in all respect. Cft 120 0
3 Backfilling / Earth Fill with the same excavated Soil in 6" layers and with compaction Cft 10 0
4 Backfilling / Earth Fill with borrowed Soil( with Transortation) in 6" layers and with compaction Cft 15 0
5 Stone Solling with compaction in Foundation bed Cft 160 0
Sub Total 0
CONCRETE Unit Quantity Rate Amount
6 Provide and lay cement concrete with 1:2:4 ratio to achieve minimum specified compressive strengths 3000 psi at 28 days using good quality sand, good quality cement, good quality crushed gravel including the cost of water(Potable) formwork to be used to give a desired effect of fair face and its removal, providing required openings, having unbroken joints, compacting, vibrating through electro mechanical vibrator, continuous curing etc. Complete in all respect as per drawings and specification (excluding the cost of reinforcement). Cft 275 0
7 Provide and lay cement concrete with 1:1.5:3 ratio to achieve minimum specified compressive strengths 3700 psi at 28 days using good quality sand, good quality cement, good quality crushed gravel including the cost of water(Potable) formwork to be used to give a desired effect of fair face and its removal, providing required openings, having unbroken joints, compacting, vibrating through electro mechanical vibrator, continuous curing etc. Complete in all respect as per drawings and specification (excluding the cost of reinforcement). Cft 340 0
8 Provide and lay cement concrete with 1:4:8 ratio to achieve minimum specified compressive strengths 1000 psi at 28 days using good quality sand, good quality cement, good quality crushed gravel including the cost of water(Potable) formwork to be used to give a desired effect of fair face and its removal, providing required openings, having unbroken joints, compacting, vibrating through electro mechanical vibrator, continuous curing etc. Complete in all respect as per drawings and specification (excluding the cost of reinforcement). Cft 160 0
9 Provide and lay cement concrete with 1:4:8 ratio to achieve minimum specified compressive strengths 1000 psi at 28 days using good quality sand, good quality cement, good quality crushed gravel including the cost of water(Potable) formwork to be used to give a desired effect of fair face and its removal, providing required openings, having unbroken joints, compacting, vibrating through electro mechanical vibrator, continuous curing etc. Complete in all respect as per drawings and specification (excluding the cost of reinforcement). Cft 185 0
Sub Total 0
REINFORCEMENT Unit Quantity Rate Amount
10 Steel (minimum yields strength of 60,000 psi) Provide, cut, fabricated, place and tie in position wherever required with 20 SWG binding wire, steel reinforcement confirming to B.S. 4461-1978 and rolled from billets , including the cost of binding wire, steel chairs, pins, spacers, un-specified laps, rolling margin, wastage etc., complete in all respect. Kg 150 0
Sub Total 0
Brick/Block Masonry Unit Quantity Rate Amount
11 Provide and lay brick masonry with best quality solid burnt bricks of approved quality, setting the bricks in 1.4 cement sand mortar raked joints including curing, scaffolding, hacking of existing surface for bonding where necessary, etc, complete in all respect. Cft 370 0
12 Supply and laying of machine made CC block (1:4:8) minimum 1000 psi compressive strength with sand cement mortar 1:4 finishing and curing including scaffolding complete. Cft 350 0
Sub Total 0
C.C.Jali. Unit Quantity Rate Amount
13 Provide and fix fairfaced pre-cast C.C.Jali of 1:4 cement sand mortar (double jali 2" thick each, total thickness 4" thick) of approved sample setting the jalis in 1:4 cement sand mortar including grouting, curing, scaffolding etc. complete in all respect. Sft 300 0
Sub Total 0
PLASTER Unit Quantity Rate Amount
14 Provide and apply 1:4 cement sand plaster of 3/4" thickness as specified including providing and fixing of 8" wide galvanized metal lathe of 18 SWG at the junctions of concrete and block/brick masonry conduct chases etc. rounded edges, drip moulds, grooves where required smooth finished in line, level, plumb, curing etc., complete in all respect. (Internal Surface) Cft 40 0
15 Provide and apply 3/4" thick 1:4 cement sand plaster sponge finish to (External surfaces) of window projections, RCC beams, face of slab including groves of 3/4" at bottom of projections, curing, scaffolding etc. complete in all respect. Sft 60 0
16 Providing & applying external brick pointing with cutting edges and filling joints with 1:4 mortar ratio including groves, cutting, curing, scaffolding etc. complete with all respect plus plinth protection Pudlo mix nero plaster of 1:4 ratio complete with all respect Sft 45 0
Sub Total 0
SUB BASE FOR FLOOR Unit Quantity Rate Amount
17 Provide and lay compacted 6" thick stone soling including over compacted earth including compacting, watering etc. complete in all respect. Cft 160 0
18 Provide and lay 3"/4" thick C.C 1:3:6 sub floor including curing etc., complete in all respect. Cft 165 0
Sub Total 0
FLOORING Unit Quantity Rate Amount
19 Provide and laying CC flooring minimum 2" thick cement concrete flooring in ration 1:2:4 including curing etc., complete in all respect. With 2x2 panel using marble/glass stips Sft 90 0
20 Provide and laying cement concrete tiles of a good manufacturer/source for flooring with 1:4 cement sand mortar base of required thickness so as to achieve a minimum over all finished floor thickness of 2", setting the tiles with neat cement mortar, grouting the joints with cement sand mortor, including curing cleaning, hacking of existing surface for bonding where necessary etc. complete in all respect. Sft 140 0
21 Provide and laying Ceramic tiles(A Class Local Made) of a good manufacturer/source for flooring with 1:4 cement sand mortar base of required thickness, setting the tiles with neat cement mortar, grouting the joints with matching gouts , including curing cleaning, hacking of existing surface for bonding where necessary etc. complete in all respect. Sft 200 0
22 Provide and laying Porcelain tiles (A Class Local made) of a good manufacturer/source for flooring with bonding mortar stting the tiles with neat mortar, grouting the joints with matching colors , including curing cleaning, hacking of existing surface for bonding where necessary etc. complete in all respect. Sft 220 0
Sub Total 0
Concrete Skirting (CC Skirting) Unit Quantity Rate Amount
23 Provide and lay 3/8" (9mm) thick, 4" (100mm) high cement concrete skirting in 1:4 cement sand mortar smooth finished with 1:4 cement sand mortar base of required thickness including curing etc. complete in all respect. Sft 250 0
Sub Total 0
Ceramic Tile Dado Unit Quantity Rate Amount
24 Provide and laying ceramic tile dado of A Class Tiles with 1:4 cement sand mortar base of required thickness setting the tile with neat cement mortar, grouting the joints with white cement mixed with approved pigment of matching colour including curing, cleaning etc., complete in all respect. Sft 320 0
Sub Total 0
Tiles border Unit Quantity Rate Amount
25 Provide and lay 65mm high tiles border of approved side and sample with 1:4 cement sand mortar base or required thickness, setting the tiles with neat cement mortar, grouting the joints with matching colour including curing, cleaning etc. complete in all respect. Cft 175 0
Sub Total 0
CC Tiles on Stair Unit Quantity Rate Amount
26 Provide and lay C.C step tiles size 12" x 8" x 1" thick on step including cost of cement sand mortar in ratio 1:4 3/4" thick and cost of 3/8" thick cement sand plaster on riser etc. complete in all respect. Cft 130 0
Sub Total 0

WOOD WORK

Panel Door Unit Quantity Rate Amount
27 Enamel painting (ICI or Berger) minimum three coats of approved shade over a coat of primer Cft 10 0
28 Provide and install door shutter 1-1/2" thick Golden teak with lassani panel, kale frames 4 " x 2" clear polish, architraves 1-1/2" x 1/2", etc. using good quality kale and Golden teak wood and other materials of approved sample as per details show, Paint finish, termite control treatment, so lignum painting (Imported make) to sides in contact to walls, columns etc. hand fasts screwed to frame, with approved hardware and fittings etc complete in all respect. Cft 10 0
Sub Total 0
Flush Door Unit Quantity Rate Amount
29 Provide and install flush door 1 1/2" thick (solid core) including wooden kale frame size 4" x 2" clear polish, architraves, etc 2" x 1/2" thick. Paint finish, termite control treatment, solignum painting (Imported make) to sides in contact to walls, columns, etc. holdfasts screwed to frame, with approved hardware and fittings etc. complete in all respect. Sft 10 0
Sub Total 0

METAL WORK

NOTE: Paint Finish: Enamel painting (ICI /Berger) minimum three, coats of approved shade over a coat of primer.

Windows and Ventilators Unit Quantity Rate Amount
30 Provide and install M.S. Window and Ventilators fabricated from approved composite sections as per details shown I/c. M.S. grills welded to windows, glass, beading, approved quality hardware, red oxide paint, enamel paint finish, etc. complete in all respect. Sft 10 0
31 Pivoted without grill Sft 450 0
32 Open able with grill Sft 700 0
33 Open able with grill (Ventilator) Sft 700 0
Sub Total 0
MS Grill Door Unit Quantity Rate Amount
34 Provide and install M.S. grills door fabricated from approved composite sections as per details shown, including paint finish/powder coated etc., complete in all respect. Sft 10 0
Sub Total 0

PAINT WORK

Distemper Unit Quantity Rate Amount
35 Provide and apply distemper (Reputable Brand) paint minimum 3 coats of approved shade and source to internal surfaces prepared smooth, with carbonados, scaffolding etc., complete in all respect. Sft 22 0
Sub Total 0
Enamel Paint Unit Quantity Rate Amount
36 Provide and apply synthetic enamel (Berger) minimum three coats of approved shades to internal surfaces prepared smooth with filling the depression with putty over a one coat of primer etc., complete in all respect. Sft 10 0
Sub Total 0

WATER PROOFING AND ROOF TREATMENT

Damp proof course. Unit Quantity Rate Amount
37 Provide and apply 2" thick 1:4 DPC smooth finished using cement mixed with pudl as per approved quality at 2.3 kg per bag of cement including curing etc. complete in all respect. Sft 100 0
Sub Total 0
Roof Treatment Unit Quantity Rate Amount
38 Provide and lay roof treatment 1:2:4 screed in panels with glass Patti area not more than 16 sft in required slope minimum thickness 2" including curing, making ridges, valleys, champhered edges, hacking of existing surface for bonding where necessary etc., complete in all respect. Sft 10 0
Sub Total 0

MISCELLANEOUS WORKS

Rain Water Vertical Channel Unit Quantity Rate Amount
39 Provide and construct 6" x 1-1/2" thick rain water vertical channel in 1:4 cement sand plaster smooth finish in required number of coats, including providing laying 3" dia PVC band at roof opening, including curing etc. complete in all respect. Sft 5000 0
Sub Total 0

Planters Unit Quantity Rate Amount
40 Floor Sft 70 0
41 Wall Sft 70 0
42 25mm dia E-class PVC drain pipe No. 50 0
43 Provide and laying 3/8" thick terrazzo coping on stair case parapet wall, FF parapit, low height walls etc. including grouting, curing etc. complete in all respect. Sft 250 0
44 Supply and Install Veneered Ply door 1 1/2" thick (solid core) including wooden kale frame size 4" x 2" clear polish, architraves, etc 2" x 1/2" thick. Paint finish, termite control treatment, solignum painting (Imported make) to sides in contact to walls, columns, etc. holdfasts screwed to frame, with approved hardware and fittings etc. complete in all respect. Sft 300 0
Sub Total 0

PVC Door Unit Quantity Rate Amount
45 Supply and Install good quality solid PVC door with Frame including hinges, Lock complete in all respect . Sft 1500 0
46 Pivoted without grill Sft 450 0
47 Open able with grill Sft 700 0
48 Open able with grill (Ventilator) Sft 700 0
Sub Total 0

MS Grill Door Unit Quantity Rate Amount
49 Supply and Install M.S. grills door fabricated including paint finish/powder coated etc., complete in all respect. Sft 800 0
Sub Total 0

Door & Windows Unit Quantity Rate Amount
50 Supply and Installlation of (Box)Super Delux Section 3" Frame Windows with 5mm Glass Sft 700 0
51 Supply and Installlation of (Box)Super Delux Section 3" Frame Windows with 5mm Tinted Glass Sft 750 0
52 Supply and Installlation of (Box)Super Delux Section 3" Frame Windows with 8mm Glass Sft 800 0
53 Supply and Installlation of (Box)Super Delux Section 3" Frame Windows with 8mm Tinted Glass Sft 850 0
54 Supply and Installlation of (Box)Super Delux Section 4" Frame Windows with 5mm Glass Sft 800 0
55 Supply and Installlation of (Box)Super Delux Section 4" Frame Windows with 5mm Tinted Glass Sft 850 0
56 Supply and Installlation of (Box)Super Delux Section 4" Frame Windows with 8mm Glass Sft 900 0
57 Supply and Installlation of (Box)Super Delux Section 4" Frame Windows with 8mm Tinted Glass Sft 950 0
58 Supply and Installlation of (Box)Super Delux Section 6" Frame Windows with 8mm with Tinted Glass Sft 850 0
59 Supply and Installlation of (Box)Super Delux Section 6" Frame Windows with 5mm Glass Sft 900 0
60 Supply and Installlation of (Box)Super Delux Section 6" Frame Windows with 5mm Tinted Glass Sft 950 0
61 Supply and Installlation of (Box)Super Delux Section 6" Frame Windows with 8mm Glass Sft 1000 0
62 Supply and Installlation of (Box)Super Delux Section 6" Frame Windows with 8mm Tinted Glass Sft 1050 0
63 Supply and Installlation of (Semi Box)Delux Section 4" Frame Windows with 5mm Glass Sft 700 0
64 Supply and Installlation of (Semi Box)Delux Section 4" Frame Windows with 5mm Tinted Glass Sft 750 0
65 Supply and Installlation of (Semi Box)Delux Section 4" Frame Windows with 8mm Glass Sft 750 0
66 Supply and Installlation of (Semi Box)Delux Section 4" Frame Windows with 8mm Tinted Glass Sft 800 0
67 Supply and Installlation of (Box)Super Delux Section 4" Collar Frame Door with 5mm Glass Sft 880 0
68 Supply and Installlation of (Box)Super Delux Section 4" Collar Frame Door with 5mm Tinted Glass Sft 930 0
69 Supply and Installlation of (Box)Super Delux Section 4" Collar Frame Door with 8mm Glass Sft 980 0
70 Supply and Installlation of (Box)Super Delux Section 4" Collar Frame Door with 8mm Tinted Glass Sft 1030 0
71 Supply and Installlation of Double A Section 3" Frame Door with 12mm Glass with all accessories Sft 850 0
72 Supply and Installlation of Double A Section 3" Frame Door with 12mm Tinted Glass with all accessories Sft 900 0
73 Supply and Installlation of Double A Section 3" Frame Door with 12mm Tinted Glass + Tempered with all accessories Sft 980 0
74 Supply and Installlation of Frameless Door with 12mm Glass with all accessories Sft 850 0
75 Supply and Installlation of Frameless Door Door with 12mm Tinted Glass Sft 900 0
76 Supply and Installlation of Frameless Door Door with 12mm Tinted Glass + Tempered with all accessories Sft 980 0
Sub Total 0

Curtain Wall Unit Quantity Rate Amount
77 Supply and Installation of Super Delux Fixed Glazing 4" section with 12mm Glass Sft 1200 0
78 Supply and Installation of Super Delux Fixed Glazing 4" section with 12mm Tinted Glass Sft 1300 0
79 Supply and Installation of Super Delux Fixed Glazing 4" section with 12mm Tinted Glass and Tempered Sft 1400 0
80 Supply and Installlation of (Box)Super Delux Section 3" Frame Windows with 5mm Glass Sft 800 0
81 Supply and Installlation of (Box)Super Delux Section 3" Frame Windows with 5mm Tinted Glass Sft 850 0
82 Supply and Installlation of (Box)Super Delux Section 3" Frame Windows with 8mm Glass Sft 900 0
83 Supply and Installlation of (Box)Super Delux Section 3" Frame Windows with 8mm Tinted Glass Sft 950 0
84 Supply and Installlation of (Box)Super Delux Section 4" Frame Windows with 5mm Glass Sft 900 0
85 Supply and Installlation of (Box)Super Delux Section 4" Frame Windows with 5mm Tinted Glass Sft 950 0
86 Supply and Installlation of (Box)Super Delux Section 4" Frame Windows with 8mm Glass Sft 1000 0
87 Supply and Installlation of (Box)Super Delux Section 4" Frame Windows with 8mm Tinted Glass Sft 1050 0
88 Supply and Installlation of (Box)Super Delux Section 6" Frame Windows with 8mm with Tinted Glass Sft 950 0
89 Supply and Installlation of (Box)Super Delux Section 6" Frame Windows with 5mm Glass Sft 1000 0
90 Supply and Installlation of (Box)Super Delux Section 6" Frame Windows with 8mm Glass Sft 1050 0
91 Supply and Installlation of (Box)Super Delux Section 6" Frame Windows with 8mm Glass Sft 1100 0
92 Supply and Installlation of (Box)Super Delux Section 6" Frame Windows with 8mm Tinted Glass Sft 1150 0
93 Supply and Installlation of (Semi Box)Delux Section 4" Frame Windows with 5mm Glass Sft 800 0
94 Supply and Installlation of (Semi Box)Delux Section 4" Frame Windows with 5mm Tinted Glass Sft 850 0
95 Supply and Installlation of (Semi Box)Delux Section 4" Frame Windows with 8mm Glass Sft 850 0
96 Supply and Installlation of (Semi Box)Delux Section 4" Frame Windows with 8mm Tinted Glass Sft 900 0
97 Supply and Installlation of (Box)Super Delux Section 4" Collar Frame Door with 5mm Glass Sft 980 0
98 Supply and Installlation of (Box)Super Delux Section 4" Collar Frame Door with 5mm Tinted Glass Sft 1030 0
99 Supply and Installlation of (Box)Super Delux Section 4" Collar Frame Door with 8mm Glass Sft 1080 0
100 Supply and Installlation of (Box)Super Delux Section 4" Collar Frame Door with 8mm Tinted Glass Sft 1130 0
101 Supply and Installlation of Double A Section 3" Frame Door with 12mm Glass with all accessories Sft 950 0
102 Supply and Installlation of Double A Section 3" Frame Door with 12mm Tinted Glass with all accessories Sft 1000 0
103 Supply and Installlation of Double A Section 3" Frame Door with 12mm Tinted Glass + Tempered with all accessories Sft 1080 0
104 Supply and Installlation of Frameless Door with 12mm Glass with all accessories Sft 950 0
105 Supply and Installlation of Frameless Door Door with 12mm Tinted Glass Sft 1000 0
106 Supply and Installlation of Frameless Door Door with 12mm Tinted Glass + Tempered with all accessories Sft 1080 0
107 Supply and fixing of PVC Door with frame and including all accessories Sft 1200 0
108 Supply and Installation of Super Delux Fixed Glazing 4" section with 12mm Glass Sft 1300 0
109 Supply and Installation of Super Delux Fixed Glazing 4" section with 12mm Tinted Glass Sft 1400 0
110 Supply and Installation of Super Delux Fixed Glazing 4" section with 12mm Tinted Glass and Tempered Sft 1500 0
Sub Total 0

Paint Work Unit Quantity Rate Amount
111 Surface preparation of new surface using sand paper etc. Sft 10 0
112 Removal of old paint by scrapping and sand paper or using grinder wherever required. Sft 20 0
Sub Total 0

Distemper Unit Quantity Rate Amount
113 Provide and apply distemper (Reputable Brand) paint minimum 3 coats of approved shade and source to internal surfaces prepared smooth, with carbonados, scaffolding etc. Sft 22 0
Sub Total 0

Enamel Paint Unit Quantity Rate Amount
114 Provide and apply synthetic enamel (Reputable Brand) minimum three coats of approved shades to surfaces prepared smooth with filling the depression over one coat of primer etc., complete in all respect. Sft 40 0
Sub Total 0

Matt Finish Unit Quantity Rate Amount
115 Provide and apply Matt Finish (Reputable Brand) minimum three coats of approved shades to internal surfaces prepared smooth with filling the depression with putty over a one coat of primer etc., complete in all respect. Sft 40 0
Sub Total 0

Weather Sheild Unit Quantity Rate Amount
116 Provide and apply Weathershield (Reputable Brand) minimum three coats of approved shades to external surfaces prepared smooth with filling the depression etc., complete in all respect. Sft 40 0
Sub Total 0

Decorative Surfaces Unit Quantity Rate Amount
117 Color Crete min 4mm thickness including surface preparation applied on prepared surface using Applicant Machine/Gun Sft 160 0
118 Supply and Services for Acralyic base Graphic paint in desired shade/colors complete in all respects Sft 80 0
119 Alumunium Composite Panel/Cladding (Alucobond) Sft 500 0
Sub Total 0

WATER PROOFING AND ROOF TREATMENT

Damp proof course Unit Quantity Rate Amount
120 Provide and apply 2" thick 1:4 DPC smooth finished using cement mixed with pudl as per approved quality at 2.3 kg per bag of cement including curing etc. complete in all respect. Rft 100.00 0
Sub Total 0
Roof Treatment Unit Quantity Rate Amount
121 Providing and laying roofing treatment over flat roof consisting of laying 50mm thick (minimum) C.C. 1:2:4 screed laid in required slope, applying hot bitumen of grade 70-80 having coverage of 0.86Kg/sq.m over screed, laying300 guage polythene sheet over bitumen, laying 40mm thick heavy density Polystyrene board over polythene sheet, laying wire mesh (50mmx50mm, 10SWG) over Polystyrene board and finally applying 1/2" thick cement bonded water proof agent over wire mesh complete in all respects. Sft 600.00 0
Sub Total 0

MISCELLANEOUS WORKS

Rain Water Vertical Channel Unit Quantity Rate Amount
122 Provide and construct 6" x 1-1/2" thick rain water vertical channel in 1:4 cement sand plaster smooth finish in required number of coats, including providing laying 3" dia PVC band at roof opening, including curing etc. complete in all respect. Nos 5000 0
Sub Total 0
Planters Unit Quantity Rate Amount
123 Floor Sft 70 0
124 Wall Sft 70 0
125 25mm dia E-class PVC drain pipe No 50 0
126 Provide and laying 3/8" thick terrazzo coping on stair case parapet wall, FF parapit, low height walls etc. including grouting, curing etc. complete in all respect. Rft 250 0
Sub Total 0

ELECTRICAL WORKS

Unit Quantity Rate Amount
127 Supply/Installation and connection of the LED light fittings including all mounting accessories. Nos 400 0
128 Supply/Installation and connection of capacitor type ceiling fans of 56" size with all fixing accessories, regulator, complete in all respects. (18" long rod) Nos 5500 0
Providing and installing light and fan point wiring with 3 x 1.5sq.mm single core PVC insulated 450/750V grade copper conductors in PVC conduit surface / concealed mounted including all accessories ceiling roses, 10A switches with specified cover plates, sheet steel back boxes with brass earth terminal complete in all respect. 0
130 Light point controlled by one switch. Nos 800 0
131 Light point from point to point. Nos 500 0
132 Circuit wiring from distribution board to switch/lighting point same as above but wiring 3 x 2.5sq.mm PVC wires. Nos 1500 0
133 Fan point with fan hook box including suitable size concealed G.I. Box for Fan regulator. . Nos 800 0
134 Providing and installing wiring for 5A, switch socket outlets with 3 x 1.5sq.mm single core PVC insulated copper wires in PVC conduit from nearest light point / switch concealed / surface mounted with all accessories. Sheet steel back boxes with brass earth terminal and providing and installing 5A universal switch socket outlets. Nos 500 0
135 Providing and installing of circuit wiring from DB for 13A socket outlets with 3 x 4.0sq.mm single core PVC insulated copper wires in PVC conduit surface / concealed mounted with all accessories, sheet steel back boxes with brass earth terminal and providing and installing 13A switch socket outlet. Nos 1350 0
Powder Coated 18 Guage Sheet made Distribution Board (Breakers MG, Legrand) 100Amp MCCB 4P, 4P-43A x 2, 4p-20A x1, 3P-32A x4, 2P-32A x 4, 1P-10A x 10, 1P-32A x4, 1P-20A x 4. 1 x ELCB 32A . With Input/Output Digital Voltmeter(Fuji). Digital Amp Meter Digital, Lock and Key with Sealing Spray Nos 80000 0
Supply, installation and connection of the following main, submain 450V/750V grade PVC copper cables in conduit. 0
139 4 x 1C - 16mm² PVC wires in 1 1/2" dia PVC pipe Rft 800 0
5 x 1C - 25mm² PVC wires in 2" dia PVC pipe. Rft 1500 0
6 x 1C - 35mm² PVC wires in 2" dia PVC pipe. Rft 2000 0
Sub Total 0

PLUMBING WORKS

Unit Quantity Rate Amount
140 Providing and fixing Asian type water closet (Good Quality) with Flush Tank, connecting pipe complete with all accessories and fittings waste and traps, CP flexible pipe, including tee stop cock with check nuts, all joints plugging and screwing as necessary to the structure. Nos 7000 0
141 Providing and fixing Commode (Good Quality) with Flush Tank, connecting pipe complete with all accessories and fittings waste and traps, CP flexible pipe, including tee stop cock with check nuts, all joints plugging and screwing as necessary to the structure. Nos 10000 0
142 Providing and fixing wash basin(Good Quality) with pedestal with all accessories such as: tee stop cock with check nuts, CP flexible pipe, waste pipe, waste coupling, bracket set, etc. complete including bottle trap and silicon sealant, all joint to service and drain, plugging and screwing as necessary to the structure. Nos 5000 0
143 Vanity (Good Quality) with all accessories, Basin, Counter, Pedestals, fixing with all accessories. 25000 0
Sub Total 0
Toilet Accessories Unit Quantity Rate Amount
144 Providing and fixing bathroom accessories including fixing with Rawel plug of approved quality complete in all respect (Good Quality) 0
Bib Cock Nos 1000 0
145 Pillar Cock Nos 1200 0
146 Tee Cock Nos 1000 0
147 Washroom Set (Vanity Mixer, Shower, Muslim Shower etc) Good quality local Nos 50000 0
Sub Total 0
Water Supply System Unit Quantity Rate Amount
5 Providing, fixing, jointing testing and disinfecting G.I. Pipe lines for water supply medium guage including specials, (sockets, tees, elbows bends reducers plugs and union etc. supported on walls, or suspended from roof slab or run in chase including pipe hangers supports, cutting making good the chase and holes as necessary to the structure including protective coating as per drawing and specification complete in all respect. (including colour coding) 0
148 1/2" dia Rft 0
149 1" dia Rft 0
150 1 1/4" dia Rft 0
6 Same as item no. 05, but with UPVC 0
151 1/2" dia Rft 50 0
152 3/4" dia Rft 70 0
153 1" dia Rft 90 0
6 Same as item no. 06, but with CPVC 0
154 1/2" dia Rft 50 0
155 3/4" dia Rft 70 0
156 1" dia Rft 90 0
7 Providing, fixing and connecting polyethylene O.H.W. tank of approved quality including check valve, gate valve, float valve, drain caps and accessories complete in all respect. 0
a) 300 Gallons Nos 20000 0
Sub Total 0
Internal Soil, Waste Water's System Unit Quantity Rate Amount
8 Providing and fixing in position PVC pipes for soil, waste water, vent and rain water embedded in floor and wall or suspended from slab or clamped to wall including clamps, hanger collars, supports, specials (bends, tees, Y-tee, etc) making requisite number of holes in walls and floors where required and making good the same as necessary to the structure. 0
157 4" dia Rft 250 0
158 6" dia Rft 400 0
159 Providing and constructing masonry square manhole complete in all respect including excavation backfilling compaction. M.I. Rungs benching etc. complete with C.I. Frame and cover heavy duty Alpine make. 2' x 2' 7000 0
Sub Total 0
Grand Total 0

This quotation is subject to our Terms & Conditions printed on reverse side hereof in addition to the following terms.